Referência | Gama | Precisão | ||
---|---|---|---|---|
Frequência | – | 30 – 50 Hz | 50 -60 Hz | 60 -1 kHz |
Corrente AC | 6 mA | ±(2.0%+5D) | ±(1.0%+5D) | ±(2.0%+5D) |
Corrente AC | 60 mA | ±(2.0%+5D) | ±(1.0%+5D) | ±(2.0%+5D) |
Corrente AC | 600 mA | ±(2.0%+5D) | ±(1.0%+5D) | ±(2.0%+5D) |
Corrente AC | 6A | ±(2.0%+5D) | ±(1.0%+5D) | ±(2.0%+5D) |
Corrente AC | 60 A | ±(2.0%+5D) | ±(1.0%+5D) | ±(2.0%+5D) |
Low pass filter (50-60 Hz) | 6 mA | ±(2.0%+5D) | ±(1.0%+5D) | – |
Low pass filter (50-60 Hz) | 60 mA | ±(2.0%+5D) | ±(1.0%+5D) | – |
Low pass filter (50-60 Hz) | 600 mA | ±(2.0%+5D) | ±(1.0%+5D) | – |
Low pass filter (50-60 Hz) | 6A | ±(2.0%+5D) | ±(1.0%+5D) | – |
Low pass filter (50-60 Hz) | 60 A | ±(2.0%+5D) | ±(1.0%+5D) | – |
Low pass filter (1 Hz) | 6 mA | ±(2.0%+5D) | ±(1.0%+5D) | – |
Low pass filter (1 Hz) | 60 mA | ±(2.0%+5D) | ±(1.0%+5D) | – |
Low pass filter (1 Hz) | 600 mA | ±(2.0%+5D) | ±(1.0%+5D) | – |
Low pass filter (1 Hz) | 6A | ±(2.0%+5D) | ±(1.0%+5D) | – |
Low pass filter (1 Hz) | 60 A | ±(2.0%+5D) | ±(1.0%+5D) | ±(1.0%+5D) |
Cat. de sobretensão | CAT II 1000 V, CAT III 600 V | |||
Normativa de segurança | IEC/EN 61010-1 | |||
Abertura das maxilas | 40 mm | |||
Dimensões | 100 x 230 x 24 mm | |||
Peso (baterias incluídas) | 500 g | |||
Baterias | 2x 1,5 AA LR6 | |||
Acessórios fornecidos | ||||
Baterias / Manual de instruções / Mala de transporte. | – | – | – | – |